Manuale d’uso / di manutenzione del prodotto GF3 DVII del fabbricante Jotul
Vai alla pagina of 28
Installation and Operation Instructions Jøtul GF3 D VI I Allagash Direc t V ent Gas Heater WARNING: IF THE INFORMA TION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXA CTL Y , A FIRE OR EXPLOSION MA Y RESUL T CA USING PROPERT Y D AMA GE, PERSON AL INJUR Y OR L OSS OF LIFE.
Welcome to J ø tul... Congratulations on the purchase of your new Jøtul GF3 DVII Allagash gas stove. We at Jøtul are happy youve made the decision to warm your hearth with a Jøtul product. Your new Allagash benefits from our experience as the worlds largest manufacturer of solid fuel burning appliances for over 140 years.
PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM A V AILABLE TO ANY ONE USING OR SERVICING THE APPLIANCE. KEEP THESE INSTRUCTIONS FOR FUTURE USE.
The Jøtul GF3 DVII Allagash is a Direct V ent w all furnace and is designed as a sealed combustion, air circulating gas appliance for residential applications.
Standards This appliance complies with National Safety stan- dards and is tested and listed by Intertek T esting Services of Middleton, WI In addition, the Jøtul GF3 DVII Allagash gas stove complies with and has been tested and listed as a direct vent heater and listed to ANSI Z21.
Electrical Hazard When the Allagash gas stove is installed with the optional forced air Blower Kit, the stove must be electrically grounded in accordance with local codes or , in the absence of local codes, with the current NFP A 70- National Electrical Code or CSA C22.
Clearance Requirements Minimum clearances for the GF3 DVII Allagash Rear: 4 / 102 mm Ceiling: 12 / 305 mm Corner: 4 / 102 mm Right Side: 4 / 102 mm Left Side: 10 / 254 mm (required for.
NO TE: V ertical termina tion may r esult in reduced flame height and heat output due to the suction of natural draft. · V ertical T ermination Height: In no case shall any discharge opening on the cap be less than 2' (610 mm) horizontally from the roof surface.
Restrictor Sliders First Restriction Setting - install screw into the OUTER hole of sliders. Second Restriction Setting - screw installed into MIDDLE hole of slider .
C o-linear V ent Installation The GF 3 DV Allagash may be vented through a masonry or Class A prefabricated chimney using a Co- linear Fle xible V ent system approved for use with a solid-fuel burning.
Simpson Dura- V ent Chimney Conversion Kit The GF3 DVII Allagash is approved for use with Simpson Dura-vent Chimney Kit as shown in Figure 9. These installation requirements must be followed: 1. In masonry chimney a fireclay liner must be present the entir e length of the chimney .
VENTING MUS T TERMIN A TE WITHIN THE SHADED AREAS. REMINDER #1 Any horizontal runs made directly off the rear of the stove must be 14 or less and connected immediately to a Simpson Dura- V ent 14 snorkel (#982). REMINDER #2 If more than a 12 horizontal run is needed, A VERTICAL RISE IS REQUI R ED FIRS T.
Figure 11. V ent T erminal / Overhang Clear ances V ent T erminal Clearances Figure 10. V ent T erminal Clearances - National F uel Gas C ode. A = Clearance above grade, veranda, porch , deck, or balcony : *12 inches (30 cm) minimum. B = Clearance to window or door that may be opened: 9 inches (23 cm) minimum.
Fuel Conversion The Allagash gas stove is shipped from the factory equipped as a NA TURAL GAS unit; Howev e r , the stove is shipped with the necessary gas conversion kit to convert the stove to burn propane gas.
Correct gas pressure is essential for efficient and safe operation of the Allagash gas stove. It is impor- tant that the correct gas pressure be established at the time of the installation. For more details see the Gas Pressure section of this manual.
Leak test: 1 . Mix a 50-50 solution of water and dish soap. 2 . Light appliance- see lighting instructions on page 22 of this manual or on the stove s rating pla te.
High Altitude Adjustment Installation at high altitude locations (above 2500'), makes it necessary to compensate for the thinner air (less volume of air per cubic foot). Higher altitudes affect the atmospheric pressure and heat value of some gaseous fuels.
F i g u r e 1 8 . P r oper flame picture. Log Set Installation The Allagash is equipped a one piece log set and is packaged in bubble wrap inside the firebox. The log set must be removed from the packaging and arranged in the unit prior to start up of the gas stove.
Blower Kit Contents: Blower with mounting bracket Snapstat and W iring Harness Hi/Low/Off Switch two 6mm bolts Attach the Blower 1 . Locate the two raised bosses on the bottom back of the stove. See Figure 19. The blower is mounted to the stove using these two threaded holes.
Optional W all Thermostat or Remote Control When installing a wall mounted thermostat to the Allagash it must be 750 millivolt DC two-wire circuit thermostat. The thermostat should be placed in the same room as the hea ter , typically 5 off the floor .
S ystem Check 1. PURGE TH E GAS LINE: When lighting the appliance for the first time it will take a few moments to clear the gas line of air . Once this pur ge is complete, the appliance will operate as described in the lighting instructions located on the stove s rating plate.
Operation 1 . The Allagash is equipped with an On/ Off /T -stat rocker switch or can be controlled using an optional wall mounted thermostat. A separate switch is provided for the optional forced air blower kit. 2 . When lit for the first time, the stove will emit an odor for several hours.
MODEL NAME: Jøtul GF3 D VII Allagash Dir ec t V ent SERIAL NUMBER: ______________________________ D A TE OF PU RCHASE:____________________________ NAME OF INST ALLER:___________________________ TYPE .
9 2 3 10 11 12 13 14 15 16 18 8 22 23 4 25 20 17 34 21 36 7 32 30 29 28 27 26 6 A B C 1 4 24 19 35 31 33 Illustrated Parts List 22.
Cast Iron Parts Matte Black Blue Black Ivory Green Indigo Jøtul Iron 1 Right Door 10390492 10390427 10390429 10390432 10390436 10390485 2 Left Door 10390392 10390327 10390329 10390332 10390336 103903.
24.
3. Access the lower controls. 4. Depress gas control knob slightly and turn clockwise to OFF . Do no t force . FOR Y OUR SAFETY , READ BEFORE LIGHTING .
This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that the these instructions be carefully read and understood. Jøtul pursues a policy of continual product developmen t .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Jotul GF3 DVII è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Jotul GF3 DVII - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Jotul GF3 DVII imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Jotul GF3 DVII ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Jotul GF3 DVII, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Jotul GF3 DVII.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Jotul GF3 DVII. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Jotul GF3 DVII insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.